Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.414
Filtrar
4.
BMC Ophthalmol ; 24(1): 80, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38383362

RESUMO

PURPOSE: To compare the efficacy and efficiency of self-assembled intraocular rare earth magnet and forceps in removing intraocular foreign bodies(IOFBs) undergoing 25-gauge(G) pars plana vitrectomy. METHODS: A total of 30 patients with metallic IOFB underwent 25-G PPV were enrolled into this study. Self-assembled intraocular rare earth magnet were used in 15 patients(bar group), and forceps were used in 15 patients(forceps group). Success rate of removing IOFB, time taken to remove IOFB, incidence of IOFB slippage and fall, iatrogenic retinal damages were compared between the two groups. RESULTS: There was no significant difference in success rate of removing IOFBs between the groups(93.3% and 100%, P > 0.99). The median time taken of removing FB was significantly shorter in bar group than in forceps group(112 and 295 s, P = 0.001). None of the patients in bar group had IOFB slippage and fall, or related iatrogenic retinal damage in the process of removal. In forceps group, IOFB slippage and fall during removal were observed in 7 of 15(47.6%) patients, related iatrogenic retinal injuries were recorded in 6 of 15(40.0%) patients, both were significantly higher than bar group(P = 0.003 and P = 0.017, respectively). CONCLUSIONS: Compared with forceps, the assembled intraocular magnet can greatly reduce the possibility of IOFB slippage and fall, prevent related iatrogenic retinal damage, and shorten the time taken to remove IOFB. The assembled intraocular magnet can be an useful tool in removing metallic IOFBs in PPV.


Assuntos
Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Doenças Retinianas , Humanos , Vitrectomia , Imãs , Estudos Retrospectivos , Corpos Estranhos no Olho/etiologia , Corpos Estranhos no Olho/cirurgia , Instrumentos Cirúrgicos , Doenças Retinianas/cirurgia , Doença Iatrogênica , Ferimentos Oculares Penetrantes/etiologia , Ferimentos Oculares Penetrantes/cirurgia
5.
Eye (Lond) ; 38(2): 297-302, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37532833

RESUMO

AIM: To report the clinical settings and factors predicting outcomes in scleral tears with concurrent retained intraocular foreign bodies METHODS: All cases with scleral and corneoscleral wounds with retained intraocular foreign bodies (RIOFB) from January 2014 to January 2021 were retrospectively analysed. Favourable anatomic outcome was defined as presence of globe integrity, attached retina, absence of hypotony and active inflammation at last visit. Favourable functional outcome was defined as final visual acuity (VA) > 20/200. RESULTS: Total 139 eyes were included. Mean age was 30.66 ± 13.32 years (median 29 years, IQR 17). Penetrating trauma accounted for 87.1%, rupture for 5.8%, perforation for 7.2%. In 5.8% of the eyes the injury involved zone I extending till Zone II while in 66.9% it involved Zone II and in 27.3% in Zone III. Snellen visual acuity at presentation was logMAR 2.97 ± 1.01 and at last visit was logMAR 2.38 ± 1.45 (p < 0.0001). Time between presentation and repair was 13.93 ± 19.56 h (median 7.6 h, IQR 17.17). Favourable functional outcome was seen in 34.5% eyes and 2/3rd achieved favourable anatomic outcome. Absence of endophthalmitis (OR = 6.25, p = 0.003) and ability to remove the foreign body (OR = 7.05, p = 0.003) were associated with a favourable anatomic outcome. Better presenting Snellen visual acuity (OR = 2.77, p = 0.003), manifest scleral tear (OR = 3.36, p = 0.04), and absence of endophthalmitis (OR = 50, p = 0.0009) were associated with a favourable functional outcome. CONCLUSION: A third of the cases achieved favourable visual outcome while 2/3rd achieved favourable anatomic outcome. Absence of endophthalmitis is an important factor predicting both.


Assuntos
Endoftalmite , Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Humanos , Adolescente , Adulto Jovem , Adulto , Vitrectomia , Estudos Retrospectivos , Ferimentos Oculares Penetrantes/diagnóstico , Ferimentos Oculares Penetrantes/cirurgia , Ferimentos Oculares Penetrantes/complicações , Endoftalmite/diagnóstico , Endoftalmite/terapia , Endoftalmite/complicações , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/cirurgia , Corpos Estranhos no Olho/complicações
6.
Br J Ophthalmol ; 108(2): 285-293, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-36596662

RESUMO

BACKGROUND: The visual outcome of open globe injury (OGI)-no light perception (NLP) eyes is unpredictable traditionally. This study aimed to develop a model to predict the visual outcomes of vitrectomy surgery in OGI-NLP eyes using a machine learning algorithm and to provide an interpretable system for the prediction results. METHODS: Clinical data of 459 OGI-NLP eyes were retrospectively collected from 19 medical centres across China to establish a training data set for developing a model, called 'VisionGo', which can predict the visual outcome of the patients involved and compare with the Ocular Trauma Score (OTS). Another 72 cases were retrospectively collected and used for human-machine comparison, and an additional 27 cases were prospectively collected for real-world validation of the model. The SHapley Additive exPlanations method was applied to analyse feature contribution to the model. An online platform was built for real-world application. RESULTS: The area under the receiver operating characteristic curve (AUC) of VisionGo was 0.75 and 0.90 in previtrectomy and intravitrectomy application scenarios, which was much higher than the OTS (AUC=0.49). VisionGo showed better performance than ophthalmologists in both previtrectomy and intravitrectomy application scenarios (AUC=0.73 vs 0.57 and 0.87 vs 0.64). In real-world validation, VisionGo achieved an AUC of 0.60 and 0.91 in previtrectomy and intravitrectomy application scenarios. Feature contribution analysis indicated that wound length-related indicators, vitreous status and retina-related indicators contributed highly to visual outcomes. CONCLUSIONS: VisionGo has achieved an accurate and reliable prediction in visual outcome after vitrectomy for OGI-NLP eyes.


Assuntos
Ferimentos Oculares Penetrantes , Traumatismos Oculares , Humanos , Estudos Retrospectivos , Acuidade Visual , Retina , Vitrectomia , Prognóstico , Ferimentos Oculares Penetrantes/diagnóstico , Ferimentos Oculares Penetrantes/cirurgia
8.
Semin Ophthalmol ; 39(2): 139-142, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38069614

RESUMO

The standard of care for open globe injuries is prompt surgical closure, as delay in repair is a reported risk factor for post-traumatic endophthalmitis and is associated with worse visual outcomes. This article serves as a review of the current management and outcomes of open globe injuries repaired greater than 24 hours from the time of injury, specifically evaluating the rates of endophthalmitis in cases with and without intraocular foreign bodies, visual outcomes and rates of primary enucleation or evisceration.


Assuntos
Endoftalmite , Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Humanos , Ferimentos Oculares Penetrantes/cirurgia , Ferimentos Oculares Penetrantes/complicações , Acuidade Visual , Corpos Estranhos no Olho/cirurgia , Endoftalmite/etiologia , Fatores de Risco , Estudos Retrospectivos
9.
Retin Cases Brief Rep ; 18(1): 29-31, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35921626

RESUMO

PURPOSE: We report a novel method of intraoperative localization of a retained anterior intraocular foreign body (IOFB), using a combination of ultrasound biomicrosopy and an insulated needle. METHODS: A retrospective case report of a 56-year-old man who presented with a right eye IOFB. RESULTS: On presentation, vision was decreased in the right eye to count fingers with a small subconjunctival hemorrhage, but no other signs of a penetrating laceration. Orbital CT revealed an IOFB, and the initial vitrectomy failed to retrieve the IOFB. Then, during the subsequent vitrectomy, using an ultrasound compatible needle and an ultrasound biomicrosopy, we were able to precisely locate and remove the small anterior IOFB. CONCLUSION: Retained IOFBs can lead to severe irreversible vision loss if not promptly removed. Ancillary imaging modalities and localization techniques can help locate occult IOFBs in difficult cases.


Assuntos
Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Masculino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Microscopia Acústica , Ferimentos Oculares Penetrantes/diagnóstico por imagem , Ferimentos Oculares Penetrantes/cirurgia , Corpos Estranhos no Olho/diagnóstico por imagem , Corpos Estranhos no Olho/cirurgia , Vitrectomia/métodos
10.
BMJ Case Rep ; 16(12)2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38081737

RESUMO

We present a case of an intracorneal wooden foreign body that remained undetected for 15 years following an ocular injury sustained during gardening. The patient presented with stable visual acuity despite the long-standing presence of a wooden splinter embedded in the cornea. Interestingly, Pentacam corneal tomography did not show any abnormalities despite the foreign body piercing through the corneal stroma and endothelium. This case may serve as an opportunity to re-examine the approach to managing chronic and stable intracorneal wooden foreign bodies and explore the implications of continued observation rather than surgical management.


Assuntos
Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Humanos , Corpos Estranhos no Olho/diagnóstico por imagem , Corpos Estranhos no Olho/cirurgia , Achados Incidentais , Córnea/cirurgia , Substância Própria , Ferimentos Oculares Penetrantes/diagnóstico por imagem , Ferimentos Oculares Penetrantes/cirurgia
11.
Indian J Ophthalmol ; 71(12): 3587-3594, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37991288

RESUMO

Open-globe injuries (OGI) can lead to significant visual impairment. The Ocular Trauma Score (OTS) is the most widely recognized tool for predicting visual outcomes. This review aimed to identify prognostic factors and assess the effectiveness of the OTS in predicting visual outcomes. Twenty-one articles published on PubMed and Google Scholar were analyzed. Initial visual acuity and the zone of injury were found to be the most significant prognostic factors for OGI. Other significant prognostic factors include retinal detachment/involvement, relative afferent pupillary defect, vitreous hemorrhage, vitreous prolapse, type of injury, hyphema, lens involvement, and duration from incidence of OGI to vitrectomy. Of the 21 studies evaluated, 11 investigated the effectiveness of OTS. Four studies concluded that OTS was effective overall, while six studies suggested that it was only useful in certain OGI categories. Thus, there is a need for further research to develop an optimized ocular trauma prognosticating system.


Assuntos
Ferimentos Oculares Penetrantes , Traumatismos Oculares , Descolamento Retiniano , Humanos , Prognóstico , Estudos Retrospectivos , Traumatismos Oculares/complicações , Traumatismos Oculares/diagnóstico , Traumatismos Oculares/epidemiologia , Acuidade Visual , Ferimentos Oculares Penetrantes/diagnóstico , Ferimentos Oculares Penetrantes/epidemiologia , Ferimentos Oculares Penetrantes/cirurgia , Índices de Gravidade do Trauma
12.
Ophthalmic Surg Lasers Imaging Retina ; 54(11): 666-669, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37855828

RESUMO

We describe seven patients who were attempting to repair their garage door when a spring dislodged at high velocity, resulting in open globe injury. All patients were seen at Massachusetts Eye and Ear between the years 2008 and 2023. Their final visual acuities ranged from 20/125 to no light perception. Open globe injury appears to be a risk of attempts to repair a garage door by people who are inexperienced in doing so. [Ophthalmic Surg Lasers Imaging Retina 2023;54:666-669.].


Assuntos
Ferimentos Oculares Penetrantes , Traumatismos Oculares , Humanos , Estudos Retrospectivos , Traumatismos Oculares/cirurgia , Acuidade Visual , Ferimentos Oculares Penetrantes/diagnóstico , Ferimentos Oculares Penetrantes/cirurgia , Prognóstico
13.
Ulus Travma Acil Cerrahi Derg ; 29(7): 830-833, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37409914

RESUMO

We report a case of a metallic intraocular foreign body (IOFB) retained in the anterior chamber (AC) angle that was masquerading as herpetic stromal keratitis. A 41-year-old male construction worker was referred to our ophthalmology clinic with the complaint of consistent blurred vision for 3 days in his left eye. He had no history of ocular trauma. The best-corrected visual acuity was found to be 10/10 in the right eye and 8/10 in the left eye. On slit-lamp examination of the anterior segment, the right eye was normal, while the left eye showed unilateral corneal edema and scarring, anterior lens capsule opacification, +2 cells in the AC, and the Seidel test was negative. Fundus examination was normal bilaterally. Despite there not being history of it, we still suspected ocular trauma considering the patient's occupational risk. Consequently, an orbital computed tomography imaging was performed which revealed a metallic-IOFB in the inferior iridocorneal angle. On the second follow-up day, the corneal edema regressed, and a gonioscopic examination of the affected eye was performed, showing a small foreign body embedded in the inferior iridocorneal angle of the AC. Subsequently, the IOFB was surgically removed using Barkan lens, and excellent visual results were achieved. This case emphasizes the importance of considering IOFB in the differential diagnosis of patients with unilateral corneal edema and anterior lens capsule opacification. Fur-thermore, the presence of IOFB should be definitely excluded in patients with occupational risk of ocular trauma even if there is no history of trauma. More awareness about the proper use of eye protection should be raised to circumvent penetrating ocular-trauma.


Assuntos
Opacificação da Cápsula , Edema da Córnea , Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Ceratite , Masculino , Humanos , Adulto , Ferimentos Oculares Penetrantes/diagnóstico , Ferimentos Oculares Penetrantes/cirurgia , Acuidade Visual , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/cirurgia , Câmara Anterior/lesões , Erros de Diagnóstico
14.
BMC Ophthalmol ; 23(1): 321, 2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-37452303

RESUMO

BACKGROUND: The grease-guns injury is an uncommon injury to the orbit. We present the twelfth and thirteenth cases of grease-gun injury to the orbit to be reported in the English language literature since 1964. Here we discus and review the presentation, investigation, and treatment of this unusual trauma. CASE PRESENTATION: Case 1 was a 29-year-old man who presented 1 day after a grease-gun injury of the left orbit with severe pain, marked periorbital swelling, and proptosis. Computed tomography (CT) revealed penetration of grease into his left orbit. Following surgical removal, proptosis decreased. The limitation of extraocular movement and loss of visual acuity to finger count was discovered after the initial surgery. Motility gradually returned. Visual acuity recovered after phacoemulsification, capsular tension ring and intraocular lens implantation for traumatic cataract and subluxation. Case 2 was a 6-year-old boy who was referred 2 months after a grease-gun injury for worsening swelling with sinus, necrosis and slight ptosis of the upper left eyelids. This is a case of orbital chronic inflammation from grease-gun injuries masquerading as orbital cellulitis. The imaging findings of CT and magnetic resonance imaging (MRI) are not typical. Surgical exploration and debridement was inevitable and actually relieved the symptoms. CONCLUSIONS: Grease-gun injuries can damage the orbit in different degrees. Careful history inquiry and taking is important to establish the diagnosis. Imaging examinations using CT or MRI are helpful to determine depth of trauma and foreign bodies in the orbit at diagnosis. We suggest that surgical exploration and debridement is a key step in the management.


Assuntos
Exoftalmia , Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Armas de Fogo , Masculino , Humanos , Criança , Adulto , Órbita/diagnóstico por imagem , Órbita/cirurgia , Órbita/lesões , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/cirurgia , Ferimentos Oculares Penetrantes/diagnóstico , Ferimentos Oculares Penetrantes/cirurgia , Hidrocarbonetos
15.
J Craniofac Surg ; 34(6): e592-e593, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37317002

RESUMO

The authors report a case of an intraorbital wooden foreign body that was misinterpreted as a radiolucent area of retained air on a computed tomography (CT) scan. A 20-year-old soldier presented to an outpatient clinic following an impingement with a bough while cutting down a tree. He had a 1-cm-deep laceration on the inner canthal area of his right eye. A military surgeon explored the wound and suspected a foreign body, but could not find or extract anything. Thereafter, the wound was sutured and the patient was transferred. An examination revealed an acutely ill-looking man with distressing pain in the medial canthal and supraorbital area associated with ipsilateral ptosis and periorbital edema. A CT scan showed a radiolucent area suspected to be retained air in the medial periorbital area. The wound was explored. Upon removal of the stitch, yellowish pus was drained. An intraorbital piece of wood measuring 1.5 cm×0.7 cm was extracted. The patient's hospital course was uneventful. Pus culture revealed growth of Staphylococcus epidermidis . Wood has a density similar to air and fat and can be difficult to distinguish from soft tissue both on plain x-ray films and CT. In this case, the CT scan showed a radiolucent area resembling retained air. Magnetic resonance imaging is a better method of investigation in cases of a suspected organic intraorbital foreign body. Clinicians should be aware of the possibility of retention of an intraorbital foreign body in patients presenting with periorbital trauma, especially those with even a small open wound.


Assuntos
Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Corpos Estranhos , Aparelho Lacrimal , Militares , Masculino , Humanos , Adulto Jovem , Adulto , Corpos Estranhos no Olho/diagnóstico por imagem , Corpos Estranhos no Olho/cirurgia , Corpos Estranhos/cirurgia , Tomografia Computadorizada por Raios X , Ferimentos Oculares Penetrantes/diagnóstico por imagem , Ferimentos Oculares Penetrantes/cirurgia , Madeira , Aparelho Lacrimal/lesões , Supuração/complicações , Órbita/diagnóstico por imagem , Órbita/lesões
16.
Retina ; 43(7): 1209-1212, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37339140

RESUMO

PURPOSE: To describe the construction of a novel intraocular snare and evaluate its effectiveness in intraocular foreign body (IOFB) removal. METHOD: This is a retrospective consecutive case series. Five patients underwent pars plana vitrectomy and IOFB removal using the intraocular snare constructed from modified flute needle. RESULTS: All IOFBs were successfully engaged and removed with the snare on the first attempt. Three of the 5 cases (60%) enjoyed good visual outcome (0.4-1.0) postoperatively. No complication related to the use of the snare was encountered in this case series. CONCLUSION: Intraocular foreign body snare is simple, safe, and effective in IOFB removal.


Assuntos
Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Humanos , Estudos Retrospectivos , Ferimentos Oculares Penetrantes/diagnóstico , Ferimentos Oculares Penetrantes/cirurgia , Ferimentos Oculares Penetrantes/complicações , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/cirurgia , Vitrectomia , Microcirurgia
18.
Indian J Ophthalmol ; 71(5): 2324, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37203010

RESUMO

Background: A patient with a retained intraocular metallic foreign body post-trauma was taken up for vitrectomy and intraocular foreign body removal. Unfortunately, the intraocular magnet was not available at the moment on the table! How a little bit of creativity and innovative thought helped us tide over this crisis is the content of this video. Purpose: To demonstrate magnetization of a metallic surgical instrument for temporary use in the event of unavailability of the intraocular magnet for intraocular foreign body removal. Synopsis: A ferromagnetic substance can be magnetized temporarily using an existing magnet. We obtained a general-purpose magnet and wrapped it in sterile plastic, using which we magnetized normal intraocular forceps and a Micro Vitreo Retinal (MVR) blade by giving about 20-30 strokes over the magnet in a single direction. This aligned the magnetic domains in the metal in a parallel fashion. These Do It Yourself (DIY)- magnetic instruments were then effectively utilized to remove the metallic intraocular foreign body. Highlights: The video showcases effectively harnessing the available resources and tiding over the dearth of a necessary instrument, with the right use of an innovative idea and some creativity!. Video link: https://youtu.be/QtRC-AK5FLU.


Assuntos
Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Humanos , Vitrectomia , Retina , Instrumentos Cirúrgicos , Corpos Estranhos no Olho/diagnóstico , Corpos Estranhos no Olho/cirurgia , Ferimentos Oculares Penetrantes/diagnóstico , Ferimentos Oculares Penetrantes/cirurgia
19.
Open Vet J ; 13(3): 388-393, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-37026071

RESUMO

Background: Cat scratches and ocular foreign bodies are frequent reasons for consultation in veterinary ophthalmology. Case Description: We here present an unusual case combining trauma to the cornea and lens by a cat scratch with retention of the claw in the anterior chamber. Management consisted of the removal of the claw, reconstruction of the cornea, and mechanized ablation of the lens by phacoemulsification with implantation of an artificial lens. Conclusion: The progression during the follow-up period was considered satisfactory, with positive responses to visual tests and intraocular pressure within the norms. Only dyscoria and a tear of the endothelium and Descemet membrane, secondary to the trauma, remained.


Assuntos
Cães , Corpos Estranhos no Olho , Ferimentos Oculares Penetrantes , Animais , Gatos , Cães/lesões , Cães/cirurgia , Masculino , Câmara Anterior/lesões , Câmara Anterior/cirurgia , Lesões da Córnea/cirurgia , Lesões da Córnea/veterinária , Corpos Estranhos no Olho/cirurgia , Corpos Estranhos no Olho/veterinária , Ferimentos Oculares Penetrantes/cirurgia , Ferimentos Oculares Penetrantes/veterinária , Casco e Garras , Implante de Lente Intraocular/veterinária , Cristalino/lesões , Cristalino/cirurgia , Facoemulsificação/veterinária
20.
J Craniofac Surg ; 34(2): 561-563, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36730435

RESUMO

BACKGROUND: The aim was to describe the characteristics and outcomes of patients treated for electric bicycle-related open-globe injuries (OGIs). METHODS: A retrospective chart review of all patients who presented with electric bicycle-related OGIs was performed at the Hebei Eye Hospital in North China between January 2012 and December 2018. Demographic data, injury type, presenting clinical examination findings, best-corrected visual acuity (BCVA), secondary ocular complications, necessary surgical procedures and long-term outcome data were recorded. RESULTS: Twenty-six patients with electric bicycle-related OGIs met the inclusion criteria and were enrolled in the study. Eighteen of the 26 patients (69.2%) were males. the average age of these patients was 44.0 years old. The injuries peaked in winter in the hour between 15:00 and 20:00. Among the patients, 23 (88.5%) were farm workers, 2 (7.7%) were industrial workers, 1 (3.8%) was student. The types of OGIs were 23 ruptures (88.5%), 3 penetrating injuries (11.5%). Data on zone of injuries included 1 zone I injuries (3.8%), 12 zone II injuries (46.2%), 13 zone III injuries (50.0%). Nine eyes (34.6%) had traumatic cataract, 24 eyes (92.3%) had vitreous hemorrhage, 20 eyes (79.9%) had retinal detachment, 19 eyes (73.1%) had choroidal detachment. Ten eyes (38.4%) had hand motion or worse vision at final follow-up. four eyes (15.4%) which had injuries involving all 3 zones resulted in enucleation or evisceration. With respect to BCVA, the initial BCVA was 2.7±0.3 and the final BCVA was 2.0±0.7, indicating that the patients' BCVA was significantly improved by surgery ( t =4.3, P <0.001). CONCLUSIONS: Electric bicycle-related OGIs may have severe consequences. Modern surgical techniques can increase the rate of globe salvage although final vision remains poor. Therefore, increased awareness, proposed policies and suggestions should focus on regulating the use of electric bicycles and reinforcing laws and regulations to improve safety and prevent injuries.


Assuntos
Ferimentos Oculares Penetrantes , Traumatismos Oculares , Masculino , Humanos , Adulto , Feminino , Estudos Retrospectivos , Centros de Atenção Terciária , Ciclismo , Ferimentos Oculares Penetrantes/cirurgia , Acuidade Visual , China , Prognóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...